• page_head_bg

Products

IC60 C60 C65 1P 2P 3P 4P 1-63A Current is adjustable MCB Mini circuit breaker china manufacturer

Short Description:

Place of Origin: Zhejiang, China

Brand Name: LCELE

Model Number: Adjustable Mini

Type: MINI

Poles Number: 3

Rated voltage: 230/400V

Product name: Miniature Circuit Breaker


Product Detail

Product Tags

Function

•Can be used in homes, offices, buildings and industries
•Overload protection
•Short circuit protection
•Isolation
•Control

Technical data

•Standard: 60898-1
•Rated voltage: AC 230/400V
•Rated current(A):1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
•Tripping curve: B, C, D
•Rated short-circuit capacity(Icn): 10kA
•Rated service short circuit breaking capacity(Ics):7.5KA
•Rated frequency: 50/60Hz
•Energy limiting class: 3
•Rated impulse withstand voltage: 6.2KV
•Electrical endurance: 8000
•Contact position
•Connection capacity: Rigid conductor up to 25mm²
•Terminal connection height: 19mm

Model Tripping curve Rated voltage(V)  Poles Breaking capacity Icn Width  
EBS9B B,C,D 230/400VAC 1P, 2P, 3P, 4P 10000A,15000A 19mm  

Feature

•Elegant appearance; cover and handle in arc shape make comfortable operation.
•Contact position indicating window
•Transparent cover designed to carry label
•In case of overload, to protected circuit, MCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.
•High short circuit capacity 10KA for whole range and 15KA capacity for current rating up to 40A. thanks to the powerful electric arc extinguishing system.
• Long electrical endurance up to 6000 cycles thanks to quick making mechanism.
• Handle padlock device
• MCB handle can be locked either at”ON” position or at :o ff” position to prevent unwanted operation of the product.
• Screw terminal lock device
•The lock device prevents unwanted or casual dismounting of connected terminals

 Tripping Curve( MCB circuit breaker )

•Curve B: (3~5 In) protect and control circuit against overload and short circuit; protect people and length cables in TN and IT systems.
•Curve C:(5~10 In) protect and control circuit against overload and short circuit; protect resistive and inductive loads with low inrush current.
•CurveD: (10~20 In) protect and control circuit against overload and short circuit; protect circuits which supply loads with high inrush current when the circuit closing.


  • Previous:
  • Next:

  • Write your message here and send it to us